In this work, the possibility of using braces, energy dissipating devices with hysteretic behavior and viscous behavior to reinforce structures with a flexible ground floor is analyzed. The typological structural characteristics were taken from statistics of 287 structural opinions of buildings that suffered collapse and their subsequent demolition of the earthquake that occurred on September 19, 2017. The characteristics of the seismic records of September 19, 2017 obtained in sites close to the typologies of selected buildings are described, and dynamic nonlinear analyzes are carried out. The typology of six buildings was selected, of which three correspond to buildings that suffered collapse and three buildings that had to be demolished after the seismic event of September 19, 2017. Of these six buildings two were located in seismic zone II and the four remaining buildings in seismic zone III. The soil surrounding the foundation piles was modeled by linear springs. The buildings were designed using the Construction Regulations of the Federal District of 1976 since most of the damaged buildings were built at the time when that regulation was in force.
En este trabajo se analiza la posibilidad de usar contravientos, dispositivos disipadores de energía de comportamiento histerético y de comportamiento viscoso para reforzar estructuras con planta baja flexible. Las características estructurales tipológicas fueron tomadas a partir de estadísticas de 287 dictámenes estructurales de edificios que sufrieron colapso y su posterior demolición del sismo ocurrido del 19 de septiembre de 2017. Se describen las características de los registros sísmicos del 19 de septiembre de 2017 obtenidos en sitios cercanos a las tipologías de edificios seleccionadas, y se realizan análisis dinámicos no lineales. Se seleccionó la tipología de seis edificios, de los cuales tres corresponden a edificios que sufrieron colapso y tres edificios que tuvieron que ser demolidos después del evento sísmico del 19 de septiembre de 2017. De estos seis edificios dos se localizaron en la zona sísmica II y los cuatro edificios restantes en la zona sísmica III. El suelo que circunda a los pilotes de cimentación se modeló mediante resortes lineales. Los edificios fueron diseñados utilizando el Reglamento de Construcción del Distrito Federal de 1976 ya que la mayor parte de los edificios dañados fueron construidos en la época en que ese reglamento era vigente.